Hobart
500574
IronMan 240
Output30–280 A.
Duty200 A at 24 VDC, 60% duty cycle.
Input208 V and 240 V. Amperes input at rated load: 57.0 A at 208 V and 50.8 A at 240 V, on the 200 A, 60% row. A power cord with plug is included. The plug is not named.
PlugPlug named, type not printed
10 min cycle, 240V class
No duty percent printed for this outlet.
Does not pass 120V/15A
Does not pass 240V/50A
Sheet
Copied from the cited page. Not taken from another model or a review.
| Spec | Published value | Source, checked 2 November 2026 |
|---|---|---|
| Process | MIG and flux-cored. Spool-gun connection is described for aluminum wire. | Spool-gun feature and the wire-feed description |
| Output amp range | 30–280 A. | Quick specs, Welding Amp Range |
| Rated duty cycle | 200 A at 24 VDC, 60% duty cycle. | Quick specs, Rated Output |
| Input voltage and plug | 208 V and 240 V. Amperes input at rated load: 57.0 A at 208 V and 50.8 A at 240 V, on the 200 A, 60% row. A power cord with plug is included. The plug is not named. | Specifications table |
| Wire or rod size | The gun note on the sheet says .023–.045 in. (0.6–1.1 mm) wire, and the included drive roll is a dual-groove .030/.035 in. roll. Wire feed speed is 50–700 ipm. | Includes list, specifications table, and the gun note |
| Weight | 186 lb. | Product page specifications, Net Weight |
| Material thickness | Mild steel thickness range 24 ga.–1/2 in. (13 mm). | Quick specs and the opening paragraph |
Notes on the source
- The sheet says running off generator power is not recommended. There is no 120 V input row.
Manufacturer page · Job check · Hobart
From the table
What output does the IronMan 240 publish?
30–280 A. Source: https://contenthub.itwwelding.com/api/public/content/hobart-welding-products/spec-sheet/PIM/a43585-ironman-240-287788.pdf
What duty cycle does the IronMan 240 publish?
200 A at 24 VDC, 60% duty cycle. Source: https://contenthub.itwwelding.com/api/public/content/hobart-welding-products/spec-sheet/PIM/a43585-ironman-240-287788.pdf
What input does the IronMan 240 publish?
208 V and 240 V. Amperes input at rated load: 57.0 A at 208 V and 50.8 A at 240 V, on the 200 A, 60% row. A power cord with plug is included. The plug is not named.
Which processes does the IronMan 240 publish?
MIG, flux-cored.