WeldFactsSheet numbers only

Home ModelsMillermatic 252

Miller · 907321

Millermatic 252

Miller

907321

Millermatic 252

Output30–300 A.
Duty200 A at 24 VDC, 60% duty cycle. 250 A at 26.5 VDC, 40% duty cycle.
Input208/240 V, single-phase, 60 Hz, or 230/460/575 V, single-phase, 60 Hz. On the 208/240 V row, amps input at the 200 A, 60% rating are 57.0 A at 208 V and 50.8 A at 240 V.
PlugPlug not printed
10 min cycle, 240V class

No duty percent printed for this outlet.

Does not pass 120V/15A

Does not pass 240V/50A

Sheet

Copied from the cited page. Not taken from another model or a review.

SpecPublished valueSource, checked 2 November 2026
Process MIG (GMAW) and flux-cored (FCAW). Quick specs, Processes
Output amp range 30–300 A. Quick specs, Amperage Range, and the specifications table
Rated duty cycle 200 A at 24 VDC, 60% duty cycle. 250 A at 26.5 VDC, 40% duty cycle. Quick specs, Rated Output
Input voltage and plug 208/240 V, single-phase, 60 Hz, or 230/460/575 V, single-phase, 60 Hz. On the 208/240 V row, amps input at the 200 A, 60% rating are 57.0 A at 208 V and 50.8 A at 240 V. Quick specs, Input Power, and the specifications table
Wire or rod size Solid/stainless steel .023–.045 in. (0.6–1.2 mm). Flux-cored .030–.045 in. (0.8–1.2 mm). 12 in. spool. Specifications table, wire type and diameter
Weight 205 lb. (93 kg). Quick specs, Net Weight
Material thickness Not published by manufacturer Quick specs and the specifications table do not print a material thickness.

Notes on the source

Manufacturer page · Job check · Miller

From the table

What output does the Millermatic 252 publish?

30–300 A. Source: https://contenthub.itwwelding.com/api/public/content/miller-electric-mfg-llc/spec-sheet/PIM/9022a4-dc12-49.pdf

What duty cycle does the Millermatic 252 publish?

200 A at 24 VDC, 60% duty cycle. 250 A at 26.5 VDC, 40% duty cycle. Source: https://contenthub.itwwelding.com/api/public/content/miller-electric-mfg-llc/spec-sheet/PIM/9022a4-dc12-49.pdf

What input does the Millermatic 252 publish?

208/240 V, single-phase, 60 Hz, or 230/460/575 V, single-phase, 60 Hz. On the 208/240 V row, amps input at the 200 A, 60% rating are 57.0 A at 208 V and 50.8 A at 240 V.

Which processes does the Millermatic 252 publish?

MIG, flux-cored.