WeldFactsSheet numbers only

Home ModelsRebel EMP 215ic

ESAB

Rebel EMP 215ic

ESAB

NO SKU ON SHEET

Rebel EMP 215ic

OutputMIG setting range: 15 A / 14.75 V to 130 A / 20.5 V on 120 V, and to 235 A / 26.0 V on 230 V. TIG: 5 A to 130 A on 120 V and to 200 A on 230 V. Stick: 6 A to 130 A on 120 V and 16 A to 180 A on 230 V.
DutyMIG, 230 V: 205 A / 24.25 V at 25% and 235 A / 26 V at 15%. MIG, 120 V, 20 A breaker: 130 A / 20.5 V at 20%. TIG, 230 V: 180 A / 17.2 V at 30%. Stick, 230 V: 180 A / 27.2 V at 25%. The table prints more duty points at 40%, 60%, and 100%.
Input120 V or 230 V, 1-phase, 50/60 Hz, ±10%. Imax MIG: 20.8 A on a 15 A breaker and 28.6 A on a 20 A breaker at 120 V; 30 A at 230 V (27.6 A at 25% duty cycle). The installation guide’s maximum recommended time-delay fuse or breaker is 30 A, and the maximum normal fuse is 50 A, for both supply voltages. Input current at maximum output in that guide is 30 A.
PlugPlug not printed
10 min cycle, 120V

20% · 2.0 min on · 8.0 min off · 130 A

First percent on the sheet for this voltage. MIG, 120 V, 20 A breaker: 130 A / 20.5 V at 20%.

10 min cycle, 240V class

25% · 2.5 min on · 7.5 min off · 205 A

First percent on the sheet for this voltage. MIG, 230 V: 205 A / 24.25 V at 25% and 235 A / 26 V at 15%.

Sheet

Copied from the cited page. Not taken from another model or a review.

SpecPublished valueSource, checked 2 November 2026
Process GMAW (MIG), GTAW (TIG), and SMAW (stick). Flux-cored wire is listed in the wire-diameter table. Manual 0463 789 001, technical data and section 5.2
Output amp range MIG setting range: 15 A / 14.75 V to 130 A / 20.5 V on 120 V, and to 235 A / 26.0 V on 230 V. TIG: 5 A to 130 A on 120 V and to 200 A on 230 V. Stick: 6 A to 130 A on 120 V and 16 A to 180 A on 230 V. Technical data, setting range
Rated duty cycle MIG, 230 V: 205 A / 24.25 V at 25% and 235 A / 26 V at 15%. MIG, 120 V, 20 A breaker: 130 A / 20.5 V at 20%. TIG, 230 V: 180 A / 17.2 V at 30%. Stick, 230 V: 180 A / 27.2 V at 25%. The table prints more duty points at 40%, 60%, and 100%. Technical data, permissible load
Input voltage and plug 120 V or 230 V, 1-phase, 50/60 Hz, ±10%. Imax MIG: 20.8 A on a 15 A breaker and 28.6 A on a 20 A breaker at 120 V; 30 A at 230 V (27.6 A at 25% duty cycle). The installation guide’s maximum recommended time-delay fuse or breaker is 30 A, and the maximum normal fuse is 50 A, for both supply voltages. Input current at maximum output in that guide is 30 A. Technical data, primary current, and section 4.3.1
Wire or rod size Mild steel solid wire .023–.035 in. (0.6–0.9 mm). Stainless solid wire .030–.035 in. (0.8–0.9 mm). Flux-cored wire .030–.045 in. (0.8–1.1 mm). Aluminum .030–3/64 in. (0.8–1.2 mm). Spool size 4–8 in. Technical data, wire diameter
Weight 42 lb (19.1 kg). Dimensions 23 × 9 × 16 in. Technical data, weight
Material thickness Not published by manufacturer The technical-data chapter does not print a plate thickness.

Notes on the source

Manufacturer page · Job check · ESAB

From the table

What output does the Rebel EMP 215ic publish?

MIG setting range: 15 A / 14.75 V to 130 A / 20.5 V on 120 V, and to 235 A / 26.0 V on 230 V. TIG: 5 A to 130 A on 120 V and to 200 A on 230 V. Stick: 6 A to 130 A on 120 V and 16 A to 180 A on 230 V. Source: https://ldgsesabwe.blob.core.windows.net/instructionmanuals/0463%20789%20001%20US.pdf

What duty cycle does the Rebel EMP 215ic publish?

MIG, 230 V: 205 A / 24.25 V at 25% and 235 A / 26 V at 15%. MIG, 120 V, 20 A breaker: 130 A / 20.5 V at 20%. TIG, 230 V: 180 A / 17.2 V at 30%. Stick, 230 V: 180 A / 27.2 V at 25%. The table prints more duty points at 40%, 60%, and 100%. Source: https://ldgsesabwe.blob.core.windows.net/instructionmanuals/0463%20789%20001%20US.pdf

What input does the Rebel EMP 215ic publish?

120 V or 230 V, 1-phase, 50/60 Hz, ±10%. Imax MIG: 20.8 A on a 15 A breaker and 28.6 A on a 20 A breaker at 120 V; 30 A at 230 V (27.6 A at 25% duty cycle). The installation guide’s maximum recommended time-delay fuse or breaker is 30 A, and the maximum normal fuse is 50 A, for both supply voltages. Input current at maximum output in that guide is 30 A.

Which processes does the Rebel EMP 215ic publish?

MIG, flux-cored, stick, TIG.